Multi Meter

Multi Meter

A digital multimeter is a device that measures two or more electrical quantities, primarily voltage (volts), current (amps), and resistance (ohms) (ohms). For technicians in the electrical and electronic industries, it is a typical diagnostic tool.

Show All Items

 

Sort By:

Reset

 

Item Code

Product Detail

Unit

QTY

Unit Price

T. Price

Add to Enquiry

UT89XE Digital Multimeter

Pcs

AED 250.56

AED 250.56

 Technical Specifications

Specifications   UT89XE
Safety ratings CAT II 1000V, CAT III 600V
DC voltage (V) 200mV/2V/20V/200V/1000V ±(0.05%+5)
AC voltage (V) 200mV/2V/20V/200V/1000V ±(0.8%+25)
DC current (A) 2000μA/200mA/20A ±(0.5%+4)
AC current (A) 2000uA/200mA/20A ±(1.5%+15)
Resistance (Ω) 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ/200MΩ ±(0.4%+5)
Capacitance (F) 200mF ±(4%+50)
Conductance (ns) 200nS ±(1.2%+50)
Frequency (Hz) 60MHz ±(0.1%+3)
Temperature (℃)  -40℃~1000℃ ±(1%+10)
Temperature (℉)  -40℉~1832℉ ±(1.5%+10)
Audible/visual alarm V/A/Cap/Diode
MAX/MIN  
Peak Hold  
LPF measurement  
General Characteristics
Power 1.5V battery (R03) x 4
Display 61mm x 36mm
Product net weight 345g
Product size 189mm x 89mm x 53mm
Standard accessories Batteries, test lead,  k-type temperature probe, English manual
Standard individual packing Gift box
Standard quantity per carton 20pcs
Standard carton measurement 450mm x 355mm x 340mm
Standard carton gross weight 12.2kg

Models & Comparison

Specifications   UT89X UT89XD UT89XE
Safety ratings CAT II 1000V, CAT III 600V
DC voltage (V) 600mV/6V/60V/600V/1000V ±(0.5%+2) ±(0.5%+2)  
200mV/2V/20V/200V/1000V     ±(0.05%+5)
AC voltage (V) 6V/60V/600V/1000V ±(0.8%+5) ±(0.8%+5)  
200mV/2V/20V/200V/1000V     ±(0.8%+25)
DC current (A) 60μA/60mA/600mA/20A ±(0.8%+8)    
60μA/6mA/60mA/600mA/20A   ±(0.8%+8)  
2000μA/200mA/20A     ±(0.5%+4)
AC current (A) 60mA/600mA/20A ±(1%+12) ±(1%+12)  
2000uA/200mA/20A     ±(1.5%+15)
Resistance (Ω) 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ ±(0.8%+3) ±(0.8%+3)  
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ/200MΩ     ±(0.4%+5)
Capacitance (F) 100mF  ±(2.5%+20) ±(2.5%+20)  
200mF     ±(4%+50)
Conductance (ns) 200nS     ±(1.2%+50)
Frequency (Hz) 9.999Hz/9.999MHz ±(0.1%+4) ±(0.1%+4)  
60MHz     ±(0.1%+3)
Duty cycle 0.1%~99.9% ±(2%+5) ±(2%+5)  
Temperature (℃)  -40℃~1000℃ ±(2%+4)   ±(1%+10)
Temperature (℉)  -40℉~1832℉ ±(2%+8)   ±(1.5%+10)
Live wire test      
LED test     12V  
Audible/visual alarm V/A/Cap/Diode Live/hFE/NCV LED/hFE/NCV
Transistor Hfe    
Dual range NCV test    
Flashlight    
MAX/MIN      
Peak Hold      
LPF measurement      
General Characteristics
Power 1.5V battery (R03) x 4
Display 61mm x 36mm
Product net weight 345g
Product size 189mm x 89mm x 53mm
Standard accessories Batteries, test lead,  k-type temperature probe (UT89X/UT89XE), English manual
Standard individual packing Gift box
Standard quantity per carton 20pcs
Standard carton measurement 450mm x 355mm x 340mm
Standard carton gross weight 12.2kg

Cash on delivery available
Returns not allowed
MULTI METER DT830

Pcs

AED 8.64

AED 8.64

MULTI METER

Cash on delivery available
Returns not allowed
UNI-T Multi Meter

Pcs

AED 39.96

AED 39.96

UNI-T UT33C Digital Palm Size Multi Meter Voltmeter Ammeter Resistance LCR and Temperature with Backlight

Cash on delivery available
Returns not allowed
Multi Meter Digital Safety Function 500V AC/DC -TMM 7201

Pcs

AED 34.02

AED 34.02

 

 

 

Cash on delivery available
Returns allowed
UT33A+ Palm Size Multimeter

Pcs

AED 50.76

AED 50.76

1. Clear LCD display

2. Comfortable protective cover, with test lead hanging groove

3. 2 meters drop test, precision protection

4. Loud buzzer sound; Ergonomic design

Specifications Range UT33A+
DC voltage (V) 200mV/2V/20V/200V/600V ±(0.5%+2)
AC voltage (V) 600V ±(0.7%+3)
DC current (A) 10A ±(1%+2)
AC current (A) 10A ±(1.2%+3)
Resistance (Ω) 200Ω/2kΩ/20kΩ/200kΩ
/2MΩ/20MΩ/200MΩ
±(0.8%+2)
Capacitance (F) 2mF ±(4%+8)
Features
Display count   2000
Auto power off/Auto backlight off  
Diode test/Continuity buzzer  
2m drop test/ Test probe holder  
Range selection   Auto
General Characteristics
Power 1.5V battery (R03) x 2
Display 66mm x 51mm
Product net weight Red and grey
Product color 206g (batteries included)
Product size 134mm x 77mm x 47mm
Standard accessories Batteries, test leads
Standard individual packing Gift box, English manual
Standard quantity per carton 60pcs
Standard carton measurement 640mm x 310mm x 350mm
Standard carton gross weight 18.6kg

Cash on delivery available
Returns not allowed
UT123D Smart Digital Multimeter

Pcs

AED 113.40

AED 113.40

● True RMS

● NCV/Live

● Low Battery Indication: ≤2.7V

● Data Hold

● Auto Power Off

● Acousto-optic indication: NCV/continuity/battery power

Specifications Range UT123D
Certifications CE, RoHS
Category ratings CAT III 600V
DC voltage (V)  600V ±(0.5%+3)
AC voltage (V) 600V ±(0.8%+3)
DC Current (A) 10A ±(1%+3)
AC Current (A) 10A ±(1.2%+3)
Resistance (Ω) 40MΩ ±(0.8%+2)
Capacitance (F) 4000μF ±(4%+5)
General Characteristics
Power 1.5V battery (R03) x 2
Display 44mm x 26mm
Product net weight 130g
Product size 130mm x 65mm x 28mm
Standard accessories English manual
Standard individual packing Gift box
Standard quantity per carton 60pcs
Standard carton measurement 480mm x 340mm x 325mm
Standard carton gross weight 16.1kg

Cash on delivery available
Returns not allowed
Fluke 279 FC Digital Multimeter with Integrated Thermal

Pcs

AED 3,788.64

AED 3,788.64

Features

Fluke 279 FC True-rms Thermal Multimeter helps you find, repair, validate, and report many electrical issues quickly so that you are confident problems are solved.

Locate the problem immediately
Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that can check hot spots on high-voltage equipment and transformers, and detect heating of fuses, wires, insulators, connectors, splices and switches. Scanning with the 279 FC’s thermal imager reveals many electrical issues rapidly and from a safe distance. By combining two tools into one, the thermal multimeter lightens the load and increases productivity.

 

Expanded functionality
Compatible with iFlex® (a flexible current clamp) to expand your measurement capabilities and get into tight, hard to reach spaces for current measurement (up to 2500 A AC). The large full-color LCD screen makes for easier and clearer viewing of images and readings. The 10 hour+ rechargeable battery keeps you going all day long under normal conditions.

Communicate your results
With built-in Fluke Connect®, transmit results wirelessly to a smartphone and save time on reporting to validate work is complete. Troubleshoot better by instantly trending and monitoring measurements live on your smartphone screen. Create and email reports right from the field.

 

  • Full-featured multimeter with built-in thermal imager
  • 15 measurement functions including: voltage ac and dc, resistance, continuity, capacitance, diode test, Min/Max/Avg, current ac with included iFlex current probe, frequency
  • Low-pass filter for troubleshooting adjustable speed drives
  • Thermal imaging reveals hots spots that may indicate electrical issues quickly and safely
  • Two-in-one tool is designed to increase productivity – no need to go back to the truck or office to retrieve a shared camera – so you can do more in less time!
  • iFlex expands your measurement capabilities – get into tight, hard to reach spaces for current measurement (up to 2500 A ac)
  • Save measurements and images while communicating wirelessly with a smart phone up to 20 feet / 6.1 m away (no obstructions)
  • 102×77 image resolution offers immediate visual cues of hot, potentially troublesome areas
  • 3.5 in /8.89 cm color LCD screen
  • Rechargeable lithium ion battery allows for a for a full work day (10+ hours) under normal conditions; a second battery option means you will always have a battery ready to install.
  • Assembled in the USA
  • Three year standard warranty
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Designed for durability, built to withstand a 1 m (3 ft) drop, double insulated with raised rubber holster for increased protection

What's Included?

  • Includes 279 FC TRMS Thermal Multimeter
  • TL75 Test Leads
  • rechargeable lithium
    ion battery and charger

Specifications

DMM
Basic dc accuracy 0.09%
Bandwidth 1E Hz to 65 Hz, full time low pass filter
Voltage ac/dc 1000 V
Current ac 2500 A with included iFlex Flexible Current Probe
Resistance 50 MΩ
Frequency 100 kHz
Capacitance 9,999 µF
Continuity with beeper Yes
Diode test Yes
Min/Max recording Yes
Display Hold Yes

 

Infrared camera
Infrared resolution 102 x 77
Image capture frequency 8 Hz
Field of View 36° (w) x 27° (h)
NETD ≤200 mK
Infrared spectral band 7.5 to 14 microns
Center point Yes (with center point temp)
Focus mechanism Fixed focus
Temperature Range (selectable °C and °F) -10 °C to 200 °C (14 °F to 392 °F) Accuracy: ±5 °C (9 °F) or (±5% as tested)
Emissivity 0.95 fixed
Background compensation 20 °C fixed
Memory storage Approximately 100 images (internal)
File format Non-radiometric .is2

 

General specifications
Battery type Rechargeable lithium ion battery (charge time: 4.5 hours)
Operating temperature -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature -20 ºC to 60 ºC (-4 °F to 140 °F)
Relative humidity 0% to 90% (0 °C to 35 °C) (32 °F to 95 °F)
0% to 75% (35 °C to 40 °C) (95 °F to 104 °F)
0% to 45% (40 °C to 50 °C) (104 °F to 122 °F)
Altitude 2,000 meters (6,561 feet)
Temperature coefficient Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C (°F above 82 °F or below 64° F)
Ingress Protection (IP) IP40 (non-operating)
Wireless frequency 2.4 GHz ISM Band, 20 meter range
Certifications CE, CSA, FCC
Safety compliance IEC 61010-1: Pollution degree 2; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V
EMC EN 61326-1:2012
Size 215.9 x 93.9 x 57.1 mm (8.5 x 3.7 x 2.25 in)
Weight 0.793 kg (1.75 lb)
Warranty Limited three-year warranty

Cash on delivery available
Returns not allowed
FLUKE 179 True RMS Digital Multimeter 1000V AC/DC:10A AC/DC

Pcs

AED 0.00

AED 0.00

Features

The Fluke 179 True-RMS DMM is the industry-standard troubleshooting tool for electrical and electronic systems.

With its precision, reliability, and ease of use, the Fluke 179 is the preferred solution for professional technicians around the world. It includes the features you need to troubleshoot and repair electrical and electronic systems, plus a backlit digital display, analog bar graph, and built-in temperature measurements.

 

Works When You Need It, Where You Need It

You can trust the rugged reliable Fluke 179 to get the job done in all of the messy, loud, high energy, and high altitude places you work. Whether you need a multimeter for industrial troubleshooting or electrical and electronic system installation or maintenance, the Fluke 179 with its true-RMS capabilities can do the job. It is independently tested for safe use in CAT III 1000 V, CAT IV 600 V environments and backed by a lifetime warranty.

 

Just One of Fluke’s Trusted Tools

Fluke builds the most trusted tools in the world, which means more than just the Fluke 179. If you work with HVAC equipment, work in the electrical installer’s and repairman’s world or need a small meter for small spaces, check out the full family of Fluke digital multimeters.

 

Other useful features:

  • A full-featured, precision multimeter for troubleshooting electrical and electronic systems
  • Delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
  • Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
  • Includes a built-in thermometer to measure temperature without having to carry a separate instrument
  • Safety rated CAT III 1000 V, CAT IV 600 V
  • Comes with a lifetime warranty
  • Allows closed-case calibration through front panel
  • Includes ergonomic case with integrated protective holster

What's Included?

  • 80BK Temperature Probe
  • Installed 9V battery
  • Test leads
  • Users manual

Specifications

Specifications
Voltage DC Accuracy1 ±(0.09% + 2)
Max. resolution 0.1 mV
Maximum 1000 V
Voltage AC Accuracy1 ±(1.0% + 3)
Max. resolution 0.1 mV
Maximum 1000 V
Current DC Accuracy1 ±(1.0% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Current AC Accuracy1 ±(1.5% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Resistance Accuracy1 ±(0.9% + 1)
Max. resolution 0.1 Ω
Maximum 50 MΩ
Capacitance Accuracy1 ±(1.2% + 2)
Max. resolution 1 nF
Maximum 10,000 µF
Frequency Accuracy1 ±(0.1% + 1)
Max. resolution 0.01 Hz
Maximum 100 kHz
Temperature Accuracy1 ±(1.0% + 10)
Max. resolution 0.1°C
Range -40°C / 400°C
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature -10°C to +50°C
Storage temperature -30°C to +60°C
Humidity (without condensation) 0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IV
Agency approvals UL, CSA, TÜV listed and VDE Pending
Mechanical and General Specifications
Size 43 x 90 x 185 mm
Weight 420 g
Warranty Lifetime
Battery life Alkaline ~200 hours typical, without backlight

Cash on delivery available
Returns not allowed
FLUKE 87V-MAX True-rms Digital HD Multimeter – 1000V

Pcs

AED 2,420.28

AED 2,420.28

Features

Product overview: Fluke 87V MAX True-rms Digital Multimeter

The 87V MAX contains all the trusted features of the most popular DMM used today, the Fluke 87V, plus much more.

 

Withstands drops up to 4-meters (13 feet)

Fluke’s most rugged digital multimeter. The 87V MAX is built with an industrial strength case and a removable holster. The holster doubles as a test probe holder for one-handed operation.

 

IP67 rated

Fully waterproof and dust proof, to work reliably in all the places that you need to work.

 

Withstands heat and cold

The meter has an extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.

 

Other product highlights

  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Measure up to 1000 V ac and dc
  • Measure up to 10 A (20 A for 30 seconds)
  • Frequency to 200 kHz
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
  • Min/Max/Average recording, plus 250 μs Peak min-max to capture variations automatically
  • Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment
  • Large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility
  • Hi resolution 19,999 count display mode
  • Long battery life (800 hours)

 

Comparison – 87V MAX and 87V

  87V MAX 87 V
IP Rating IP 67 IP 30
Battery life 800 hours 400 hours
Drop test 4 meters 3 meters
Backlit keypad Yes No
TwistGuard™ test leads Yes No
True-rms readings ac ac
Basic dc accuracy 0.05% 0.05%
Voltage ac/dc 1000 V 1000 V
Current ac/dc 10 A 10 A
Resistance 50 MΩ 50 MΩ
EN61010-1 CAT III 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V
Warranty (years) Limited lifetime Limited lifetime

What's Included?

  • TL175 TwistGuard® test leads
  • AC175 Alligator clips
  • 80BK-A temperature probe
  • Removable holster with test lead storage
  • Three AA batteries (installed)

Specifications

Electrical Specifications
DC Voltage Range 0.1 mV to 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 0.1 mV
AC Voltage Range 0.1 mV to 1000 V
Accuracy ±(0.7% + 4) true-rms
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
DC Current Range 0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.1 µA
AC Current Range 0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) true-rms
Maximum resolution 0.1 µA
Resistance Range 0.1 Ω to 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Range 0.01 nF to 9999 μF
Accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Range 0.5 Hz to 199.99 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement range –200.0 °C to 1090 °C
–328.0 °F to 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater
–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode test Range 2 V
Resolution 0.001V
Accuracy ±(1% + 1)
Diagnostics and data storage Peak Min/Max 250 μS
Min/Max/Avg Yes
Reading hold/Auto (Touch) Hold Yes
Relative reference Yes
Display Digital 6000 counts updates 4/second
19,999 counts in high–resolution mode
Analog bar graph 32 segments, updates 40/second
Backlight Two level
Low pass filter (VFD measurements) Yes
Input Alert™ Yes
Safety Specifications
Safety rating IEC61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
Agency approvals CE, CSA
Mechanical and General Specifications
IP rating IEC 60529: IP67
Power Three AA batteries. 800 hours typical, without backlight
Size 6.0 x 10.1 x 21.5 cm (with holster)
Weight 698.5 g (with holster)
Warranty Limited lifetime
Environmental Specifications
Operating temperature -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
Storage temperature -40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating altitude 2000 m

Cash on delivery available
Returns allowed
CNX 3000 CNX Wireless Digital Multimeter;600V AC/DC 0.01mA

Pcs

AED 1,404.00

AED 1,404.00

Features

Work Faster, Safer and Easier with CNX Wireless Test Tools

Fluke’s CNX Wireless Test Tools put tools, not your body, near live electrical panels. It’s simple. Connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers, and read the results on the CNX 3000 Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules.

Don’t Get Bogged Down While Isolating Intermittent Electrical Faults

Timing is everything when trying to find an intermittent problem and the hard part is, it doesn’t always show up when you have your meter connected. We’ve solved that problem with CNX – leave your CNX remote modules connected to log measurements and walk away to address other issues. You can then download the data for further analysis.

Work Safely Near Electrical Panels While Wearing Less PPE

Personal protective equipment (PPE) can save your life, but it’s bulky, hot and hard to work in. With CNX, there’s no need to work in front of live open panels or moving/hazardous machinery.

Picture having the ability to access live readings without being exposed to the live panel. It’s easy. Just deenergize the cabinet, open the panel while wearing PPE and connect your CNX modules. Close the cabinet, reenergize and let the CNX multimeter work, reducing the risk of arc flash by separating yourself from hazardous measurement situations.

Testing 3-Phase is Now Faster and Cheaper

When your cabinet is deenergized, attach a CNX current clamp to each phase. Close, reenergize and start taking readings. What used to take hours and use costly equipment can be done in minutes with an affordable CNX wireless system.

Take 3-Phase Measurements in 1/3 the Time. Add your laptop and go from logging to analysis and diagnosis

You can solve problems faster by seeing live measurements from multiple test points on a single screen. With a CNX wireless test tool, you can:

  • Take 3-phase measurements in 1/3 the time
  • Add your laptop and go from logging to analysis and diagnosis
  • Record over time using the CNX wireless modules and monitor circuit load changes for an hour, a shift or a week
  • Use the CNX wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data
  • Perform for analysis with your PC and the CNX wireless test tool software. View data or graphs to see problems easily on the computer display

What's Included?

  • True-RMS Wireless Multimeter
  • TL175 Test Leads
  • AC175 Alligator Clips

Specifications

Detailed Specifications
AC Voltage
Range ⊃1; / Resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy ⊃2;, ⊃3; 45 Hz to 500 Hz 1.0 % + 3
500 Hz to 1 kHz 2.0 % + 3
  ⊃1; All AC voltage ranges are specified from 1 % of range to 100 % of range.
⊃2; Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1> ⊃3; For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mV Range ⊃1; / Resolution 600.0 mV / 0.1 mV
Accuracy 0.09 % + 2
V Range ⊃1; / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09 % + 2
0.15 % + 2
))) Range ⊃1; / Resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25>
Ω Range ⊃1; / Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5 % + 2
0.5 % + 1
1.5 % + 3
Diode test Range ⊃1; / Resolution 2.000 V0.001 V
Accuracy 1 % + 2
μF Range ⊃1; / Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF ⊃1; / 1 μF
Accuracy 1.2 % + 2
10 %
⊃1; In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range ⊃1; / Resolution 60.00 mA / 0.01 mA
400.0 mA ⊃3; / 0.1 mA
Accuracy 1.5 % + 3
mA DC ⊃2; Range ⊃1; / Resolution 60.00 mA / 0.01 mA
400.0 mA / 0.1 mA
Accuracy 0.5 % + 3
  ⊃1; All AC current ranges are specified from 5 % of range to 100 % of range.
⊃2; Input burden voltage (typical): 400 mA input 2 mV/mA.
⊃3; 400.0 mA accuracy specified up to 600 mA overload.
Frequency
  Range ⊃1; / Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 0.1 % + 1
  ⊃1; Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function    
OverloadProtection 1100 V RMS
Input Impedance
(nominal)
> 10 MΩ < 100>
Common Mode Rejection Ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal Mode Rejection > 60 dB at 50 Hz or 60 Hz
OverloadProtection 1100 V RMS
Input Impedance
(nominal)
> 10 MΩ < 100>
Common Mode Rejection Ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
OverloadProtection 1100 V RMS
Input Impedance
(nominal)
> 10 MΩ < 100>
Common Mode Rejection Ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal Mode Rejection > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage
OverloadProtection 1100 V RMS
Input Impedance
(nominal)
< 2>
Full scale To 6 MΩ: < 0> 50 MΩ: < 0>
Typical short circuit current < 350>
OverloadProtection 1100 V RMS
Input Impedance
(nominal)
< 2>
Full scale To 6 MΩ: 2.000 V DC
Typical short circuit current < 1>
mA Overload Protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration
General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) / °C (< 18> 28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54

Cash on delivery available
Returns not allowed






















Join Our Newsletter Now

Get E-mail updates about our latest shop and special offers.

Address: GooXoom.com
Salah Al Din Street
Deira, Dubai
United Arab Emirates

Phone: +971522074931

Email: support@gooxoom.com