Clamp Meter

Clamp Meter

An electrical test tool called a clamp meter combines a conventional digital multimeter with a current sensor. Clamps are used to measure current. Voltage is measured through probes. An electrical meter with a hinged jaw allows personnel to clamp the jaws around a wire, cable, or other conductor at any point in an electrical system and measure current without disconnecting or deenergizing it.

Show All Items

 

Sort By:

Reset

 

Item Code

Product Detail

Unit

QTY

Unit Price

T. Price

Add to Enquiry

FLUKE 355 True RMS Clamp Meter  Model # 355

Pcs

AED 3,319.92

AED 3,319.92

Features

Versatile and rugged tools for applications with high currents

 

Confidently take reliable readings with the True RMS, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

 

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter.
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

What's Included?

  • C43 soft carrying case
  • 6 AA batteries
  • TL224 1.5 m silicone rubber test leads
  • TP2 test probes
  • AC285 alligator clips
  • User manual
  • 3 year warranty

Specifications

Electrical Specifications
Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC rms
Crest Factor1 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Voltage measurement DC and AC 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 1% rdg + 10 digits
1% rdg + 5 digits
Trigger level for Hz filter OFF 0.25 V / 6 V
Trigger level for Hz filter ON 0.25 V / 6 V
Voltage measurement AC 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V ac rms
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 3% rdg + 10 digits
3% rdg + 5 digits
Trigger level for Hz filter OFF 0.050 V / 0.25 V / 6 V
Trigger level for Hz filter ON 0.050 V / 0.25 V / 6 V
Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ
Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω
Accuracy 1.5% + 5 digits
Continuity beeper On at ≤ 30 Ω
Off at ≥ 100 Ω
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts
Trigger level Refer to current and voltage tables
1. Add 2% to error spec for CF > 2
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg (1.8 lb)
Jaw size 58 mm (2.28 in)
Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature 32°F to +122°F (0°C to +50°C)
Storage temperature -4°F to 140°F (-20°C to +60°C)
Operating humidity 0 to 95% (non-condensing)
Operating altitude 2000 m
Storage altitude 10,000 m
IP rating 42 (indoor use only)
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325
Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C
Voltage 0.1% of reading per °C outside 22°C to 24°C

Cash on delivery available
Returns allowed
FLUKE 902 FC TRMS HVAC Clamp Meter 600V  Model # 902 FC

Pcs

AED 1,128.60

AED 1,128.60

Features

Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site.

The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.

 

Part of the Fluke Connect wireless family

As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.

 

The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.

 

  • A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
  • Offers 200 µA DC current measurements to measure flame rod
  • Extends resistance range to measure thermistors up to 60kΩ
  • Captures flue gas temperature
  • Measures start and run motor capacitors
  • Measures variable frequency drive performance
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display improves readings in low light settings
  • Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warrant
  • Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
  • Measures AC current to 600 A and AC and DC voltage to 600 V
  • Measures capacitance to 1000 µF and DC current to 200 µA
  • Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
  • Offers True-RMS voltage and current measurements to accurately measure non-linear signals
  • Measures resistance to 60 kΩ
  • Offers Min/Max recording to capture variations automatically
  • Runs on two AA alkaline batteries

What's Included?

  • TL75 test leads (1 pair)
  • 80BK integrated DMM temperature probe (1)
  • AA alkaline batteries (2)
  • Soft carrying case
  • User’s manual
  • Statement of calibration

Specifications

Function
A ac (via Jaw)
Resolution 0.01/0.1 A
Accuracy 2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range 60.00/600.0 A
Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A
3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
V ac
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
V dc
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
Ohms
Resolution 0.1/1/10
Accuracy 1% ±5 digits
Range 600/6000/60.00 kΩ
Capacitance
Resolution 0.1/1 µF
Accuracy 1% ±4 digits
Range 100.0/1000 µF
µA
Resolution 0.1 µA
Accuracy 1% ±5 digits
Range 200 µA
Contact temperature
Resolution 0.1 C/F
Accuracy 1% ±8 digits
Range -40 to 400 °C (-40 °F to 752 °F)
Continuity beeper
Beeper volume 75 dBA nom. 15 cm. from case front
On threshold <=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidity Non condensing (< 10>
Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only) 419 g (15 oz)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C

Cash on delivery available
Returns not allowed
UT207B 1000A True RMS Digital Clamp Meter

Pcs

AED 347.20

AED 347.20

1. Flashlight button: Short press thisbutton to turn on/off the flashlight.

2. Flexible current probe (optional) to extendthe AC current measurement range to3000A

3. Inrush current capture

4. NCV Multi-Segment Display and audio/visual alarm

5. True RMS/Auto backlight

6. NCV/Function retention

Specifications Range UT207B
AC current (A) 1000A ±(2%+5)
DC current (A) 1000A ±(2%+5)
AC current frequency response   40Hz~400Hz
Inrush current (A) 1000A ±(10%+10)
AC voltage (V) 6V ±(1.2%+3)
60V/600V/1000V ±(1%+8)
DC voltage (V) 600mV ±(0.8%+3)
6V/60V ±(0.5%+5)
600V ±(0.5%+5)
1000V ±(0.5%+5)
Low pas filter (LPF ACV) 600V/1000V ±(2%+5)
AC voltage frequency response   40Hz~400Hz
LoZ ACV 600V/1000V ±(2%+5)
Resistance (Ω) 600Ω ±(1%+3)
6KΩ/60KΩ/600KΩ ±(1%+2)
6MΩ/60MΩ ±(2%+8)
Capacitance (F) 60nF ±(4%+25)
600nF/6μF/60μF/600μF ±(4%+5)
6mF/60mF ±(10%+9)
Low voltage frequency (Hz) 10Hz~1MHz ±(0.1%+3)
Duty cycle (%) 10%~90% ±(2.6%+7)
Features
Display count   6000
Jaw opening   42mm
Current frequency   50Hz~60Hz
High voltage frequency   40Hz~400Hz
Analog bar   31
Auto power off  
Continuity test  
Auto/Manual range  
Low battery indication  
Diode test  
Relative mode/Data hold  
MAX/MIN  
Function selection  
Flashlight  
Wake-up function  
Auto power off current: <50μA  
Zero mode  
Input impedance (ACV/DCV) ≥10MΩ
General Characteristics
Power 1.5V battery (R03) x 3
Display 43mm x 45mm
Product color Red and grey
Product net weight 420g
Product size 272mm x 81mm x 43.5mm
Standard accessories Test leads, batteries
Standard individual packing Gift box, carrying bag, English manual
Standard quantity per carton 10pcs
Standard carton measurement 355mm x 330mm x 315mm
Standard carton gross weight About 7.1kg

Cash on delivery available
Returns not allowed
Fluke 374 FC True RMS Clamp Meter 600 A (1000V)

Pcs

AED 1,198.80

AED 1,198.80

Features

The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.

 

Use wireless connectivity to keep a safe distance

The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.

 

Versatile feature set

With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.

 

  • Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance
  • Performs AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V
  • Measures AC current to 2500 A AC with optional iFlex flexible current probe
  • Measures resistance to 6000 Ω with continuity detection

 

Other useful capabilities:

  • Compatible with optional TPAK magnetic hanging strap
  • Comes with soft carrying case, batteries, and three-year warranty
  • Measures capacitance to 1000 µF
  • Features CAT III 1000 V, CAT IV 600 V safety rating
  • Provides True-RMS voltage and current measurements to accurately measure non-linear signals
  • Includes Min/Max/Avg and inrush recording to capture variations automatically
  • Runs on two AA alkaline batteries

What's Included?

  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries
  • Coated instruction card
  • Safety information sheet

Specifications

General Specifications
AC Current via Jaw
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe Distance from Optimum
  i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Resistance
Range 6000 Ω
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity –
non-condensing (< 10>
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 3000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

Cash on delivery available
Returns not allowed
FLUKE 375FC True RMS AC/DC Clamp Meter 600A(1000V)

Pcs

AED 1,398.60

AED 1,398.60

Features

Fluke 375 FC True-RMS AC/CD Clamp Meter measures very low voltage and very high resistance

 

The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect

The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.

 

Wireless connectivity improves productivity

 

Using its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls.

Versatile performance

With True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.

Other useful capabilities:

  • Compatible with optional TPAK magnetic hanging strap
  • Comes with batteries, soft carrying case, and three-year warranty
  • Features CAT III 1000 V, CAT IV 600 V safety rating
  • Measures capacitance to 1000 µF
  • Includes True-RMS voltage and current measurements to accurately measure non-linear signals
  • Measures frequency to 500 Hz and resistance to 60 kΩ with continuity detection
  • Includes Min/Max/Avg and inrush recording to capture variations automatically
  • Offers 500 mV DC measurement range to interface with other accessories
  • Runs on two AA alkaline batteries

What's Included?

  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries
  • Coated instruction card
  • Safety information sheet

Specifications

General Specifications
AC Current via Jaw
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
   
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity – ≤90% RH (at 10 °C to 30 °C)
non-condensing (< 10> ≤75% RH (at 30 °C to 40 °C)
     
Operating altitude 3000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length 1.8 m
(head to electronics connector)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
   
   
IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

Cash on delivery available
Returns not allowed
FLUKE 373 True RMS AC Clamp Meter  Model # 373

Pcs

AED 899.64

AED 899.64

Features

Fluke 373 True RMS AC Clamp Meter does the job for any AC-only current measurement application

 

Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.

 

To make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more.

 

  • A top performing True-RMS current clamp for AC-only current measurements to 600 A
  • Measures AC and DC voltage to 600 V
  • Measures resistance to 6000 Ω with continuity detection
  • Offers state of the art signal processing to provide stable readings even in noisy electrical environments

 

Other useful capabilities:

  • Provides True-RMS voltage and current measurements to accurately measure non-linear signals
  • Automatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement
  • Presents readings on a large, easy-to-read backlit display
  • Features CAT IV 300 V, CAT III 600 V safety ratings
  • Comes with a soft carrying case and three-year warranty
  • Runs on two AA alkaline batteries
     

What's Included?

  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries

Specifications

Electrical Specifications
AC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz) 2.5 @ 600 A
AC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1 % ± 5 digits
Resistance
Range 600.0 Ω/6000 Ω
Resolution 0.1 Ω/1 Ω
Accuracy 1 % ± 5 digits
Continuity Beeper 30 Ω
Capacitance
Range 10.0 – 100.0 μF / 1000 μF
Resolution 0.1 μF/1 μF
Accuracy 1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H) 232 mm x 85 mm x 45 mm
Weight 370 g
Environmental Specifications
Operating Temperature -10 °C to +50 °C
Storage Temp -40 °C to +60 °C
Operating Humidity Non condensing (< 10> ≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMI, EMC Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
Agency Approvals  
Batteries 2 AA, NEDA 15A, IEC LR6

Cash on delivery available
Returns allowed
FLUKE 369FC Leakage Current Clamp Meter 60MM Jaw – 60A / FC

Pcs

AED 2,964.60

AED 2,964.60

Features

Detect document; record and compare leakage current readings over time as a means of preventing unplanned downtime; and identifying intermittent GFCI and RCD trips; all without taking equipment off line.

 

  • True-rms measurements for accuracy when measuring complex; non-sinusoidal waveforms
  • 61 mm jaw opening
  • Highest resolution of 1 µA; measure up to 60 A
  • Selectable filter function removes unwanted noise
  • Max/Min/Average readings and hold function
  • Forward-facing LED worklight for use in dark wiring cabinets
  • Backlit display; auto backlight off and auto power off for extended battery life
  • CAT III 600V safety rating

What's Included?

  • Leakage Clamp Meter
  • Soft case
  • Safety manual
  • Batteries: 2 AA

 

Specifications

  • Electrical Specifications
    Measurement function Alternating current
    AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
    Range selection mA / A: manual selection
    3 mA / 30 mA / 300 mA: automatic selection
    3 A / 30 A / 60 A: automatic selection
    Range / Resolution 3 mA⊃1; / 0.001 mA
    30 mA / 0.01 mA
    300 mA / 0.1 mA
    3 A / 0.001 A
    30 A / 0.01 A
    60 A / 0.1 A
    Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)⊃2; 3 mA – 30 A 1% + 5 digits
    60 A 2% + 5 digits
    Frequency 40 Hz to 1 kHz
    Crest Factor 3
    After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
    ⊃1;The minimum value is 10 μA rms.
    ⊃2;Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
    Physical
    Display (LCD) Digital readout: 3300 count
    Display refresh rate 4 times / sec
    Maximum conductor diameter 61 mm
    Dimensions 257 x 116 x 46 mm
    Weight 600 g
    Battery 2 AA, IEC LR6, NEDA 15A, alkaline
    Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
    Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity
    Safety and Environmental Specifications
    General safety IEC 61010-1: Pollution Degree 2
    Measurement safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Operating humidity Non-condensing (<10>
    90% relative humidity (10 °C to 30 °C)
    75% relative humidity (30 °C to 40 °C)
    45% relative humidity (40 °C to 50 °C)
    Protection class IEC 60529: IP30 (jaw closed)
    Operating altitude 2000 m
    Storage altitude 12000 m
    Current sensor action category IEC 61557-13: Class 1, ≤100 A / m
    Electromagnetic compatibility (EMC)
    International
    IEC 61326-1 Industrial Electromagnetic Environment
    CISPR 11 Group 1 Class B
    Group 1 Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device’s own internal functions is essential.
    Class B Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
    Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
    Class A This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per

Cash on delivery available
Returns allowed
UT221 2000A Clamp Meter

Pcs

AED 696.60

AED 696.60

UT220 series are 2000A AC/DC digitalclamp meters. This series ensures stable performance, safety, and reliability for measuring up to 2000A AC (and DC for UT221) current. It is designed with over-load protection for all ranges, perfect for all professionals measuring currents up to 2000A (2500A for UT222). 

Specifications Range UT221
AC current (A) 2000A  ±(2.5%+5)
DC current (A) 2000A  ±(2.5%+5)
AC voltage (V) 750V ±(1.2%+5)
DC voltage (V) 1000V ±(0.8%+1)
Resistance (Ω) 66MΩ ±(1%+2)
Frequency (Hz) 20MHz ±(0.1%+3)
Features
Display count   6000
Auto range/Diode  
Jaw opening   63mm
True RMS (AC voltage/AC current)  
Duty cycle 10%~90%
Continuity buzzer  
Low pass filter  
Inrush current AC current
Relative mode  
Data hold/MAX  
MIN/I-OUT function  
Analog bar graph   66
Full icon display  
Low battery indication  
Input impedance ≥10MΩ
General Characterisitics
Power 9V battery (6F22)   
Display 43mm x 30mm
Product color Red and grey
Product net weight 726g
Product size 298mm x 107mm x 47mm
Standard accessories Test leads, output cable
Standard individual packing Gift box, tool box, English manual
Standard quantity per carton 5pcs
Standard carton measurement 510mm x 375mm x 320mm
Standard carton gross weight 12.1kg

Cash on delivery available
Returns not allowed
FLUKE 324 True RMS Clamp Meter  Model # 324

Pcs

AED 627.48

AED 627.48

Features

True RMS measurements, optimized ergonomics, and a backlight display make the Fluke 324 Clamp Meter a great general purpose troubleshooting tool for commercial and residential electricians. Designed to perform in the toughest environments and provide noise-free, reliable results, you can trust the 324 to help you confidently diagnose problems. Use it to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts and to measure temperature and capacitance. Its slim, compact size and rugged design make it well suited for measuring current up to 400 A in tight cable compartments.

 

Key features:

  • Rugged, reliable True-RMS clamp meter for electrical troubleshooting
  • Measures AC current to 400 A
  • Measures AC voltage and DC voltage to 600 V
  • Provides True RMS AC voltage and current for accurate measurements on non-linear signals
  • Measures resistance to 4 kΩ with continuity detection
  • Measures temperature from -10.0°C to 400.0°C (14.0°F to 752.0°F)

 

Other useful features:

  • Measures capacitance to 1000 µF
  • Presents measurements on a large, easy-to-read backlight display
  • Hold function captures a reading on the display
  • Features a CAT III 600 V, CAT IV 300 V safety rating

What's Included?

  • Test leads
  • Soft case
  • User’s manual

Specifications

Specifications
AC current Range 40.00 A / 400.0 A
Accuracy 1.5% ± 5 digits (45 Hz to 400 Hz)
Note: Add 2% for position sensitivity
DC current Range
Accuracy
AC voltage Range 600.0 V
Accuracy 1.5% ± 5 digits
DC voltage Range 600.0 V
Accuracy 1.0% ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω
Accuracy 1.0% ± 5 digits
Continuity ≤ 30 Ω
Capacitance 0 to 100.0 μF / 100μF to 1000 μF
Frequency
AC response True-RMS
Backlight Yes
Data hold Yes
Contact temperature -10.0°C to 400.0°C (14.0°F to 752.0°F)
Min/Max
Size H x W x D (mm) 207 x 75 x 34
Max wire diameter 30 mm (600 MCM)
Weight 208 g
Category rating CAT III 600 V
CAT IV 300 V
Manufacturer Warranty Two-year

Cash on delivery available
Returns allowed
UT219DS Professional Clamp Meter

Pcs

AED 486.00

AED 486.00

1. LoZ input for ghost voltage measurement

2. Flashlight and auto backlight

3. 3-phase motor sequence test

4. Temperature and μA measurements (flame sensor)

5. Inrush current

6. AC+DC voltage

7. V+A dual display

 

 

Specifications Range UT219DS
AC current (A) 600A ±(1.8%+6)
DC current (A) 600A ±(1.8%+6)
AC voltage (V) 600V ±(1%+6)
DC voltage (V) 600V ±(0.6%+3)
LoZ ACV 600V ±(2.5%+6)
Resistance (Ω) 60MΩ ±(1%+3)
Capacitance (F)  60mF ±(4%+7)
Frequency (Hz) 600Hz~40MHz ±(0.1%+6)
Duty cycle 0.1%~99.9% ±(2.6%+7)
Temperature -40~1000℃ ±(2%+5℃)
-40~1832℉ ±(2%+9℉)
Features
Display count   6000
Auto/Manual range  
Jaw opening   33mm
True RMS  
AC current frequency response   40Hz~400Hz
AC voltage frequency response   40Hz~1kHz
3-phase motor sequence test 600V
Low pass filter 1kHz, 3db attenuation
V+A displays voltage and current at the same time  
Diode test   3V
Measurement sampling rate   5 times/s
Analog bar sampling rate   20 times/s
Analog bar    31 segment
Display interface (LCD)   Dual
Auto power off/MAX/MIN  
Low battery indication  
Data hold (H)/Relative mode (REL)  
ZERO mode  
Function selection (SELECT)  
Auto backlight/2m drop test  
IP rating   IP54
Input impedance ≥10MΩ
General Characterisitics
Power 1.5V battery (R03) x 3
Display 35mm x 31mm
Product color Red and grey
Product net weight 310g
Product size 234.6mm x 82mm x 47mm
Standard accessories Test leads, batteries, carrying bag, PC software CD, point contact temperature probe
Standard individual packing Gift box, blister, English manual (German, French, Spanish optional) 
Standard quantity per carton 10pcs
Standard carton measurement 490mm x 295mm x 330mm
Standard carton gross weight 8.2kg

Cash on delivery available
Returns not allowed






















Join Our Newsletter Now

Get E-mail updates about our latest shop and special offers.

Address: GooXoom.com
Salah Al Din Street
Deira, Dubai
United Arab Emirates

Phone: +971522074931

Email: support@gooxoom.com