An electrical test tool called a clamp meter combines a conventional digital multimeter with a current sensor. Clamps are used to measure current. Voltage is measured through probes. An electrical meter with a hinged jaw allows personnel to clamp the jaws around a wire, cable, or other conductor at any point in an electrical system and measure current without disconnecting or deenergizing it.
Voltage and current measurements with FieldSense™ technology
The Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.
Power quality indicator shows whether a problem is in the equipment or the power line
The 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.
Complete 3-phase measurements in quick, easy steps
Complete 3-phase voltage and current tests in 3 easy steps
Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
Phase rotation auto-calculated and shown on the Fluke Connect software
No more hand-written notes or complicated math.
Measure extremely high current with iFlex® probe
The included iFlex flexible current probe lets you measure ac current as high as 2500 A. Crowded wiring cabinets and large conductors are easily measured with the iFlex probe.
Easy to see, easy to use with included tools
Your job will get easier when you use the 378 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.
Record, analyze, share results with Fluke Connect® software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.
What's Included?
378 FC Non-Contact Voltage True-rms Clamp Meter
iFlex flexible current probe (18 inches; 48 cm)
TL224 silicone insulated test leads
TP175 adjustable length test probes
AC285 grounding clip (black, quantity one)
TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
Premium Carrying case
Quick reference guide
General specifications
General Maximum Voltage between any Terminal and Earth Ground
1000 V
Battery
Type
2 AA IEC LR6 alkaline
Life
200 hour
Display
Dual readout
Automatic Power Off
20 minutes
Electrical
AC Current: Jaw
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % ±5 digits (10 Hz to 100 Hz)
2.5 % ±5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)
3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range
2500 A
Resolution
1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy
3 % ±5 digits (5 Hz to 500 Hz)
Crest Factor (50/60Hz)
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
Position Sensitivity
Distance from Optimum
i2500-10 Flex
i2500-18 Flex
Error
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
± 0.5 %
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
± 1.0 %
C
1.4 in (35.6 mm)
2.5 in (63.5 mm)
± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % ±5 digits1
[1]When using the ZERO function to compensate for offsets
AC Voltage: Field Sense
Range
1000 V
Resolution
1 V (≤1000V)
Accuracy
≤4/0 AWG
3 % ±5 digits (45 Hz to 66 Hz)
≥4/0 AWG
5 % ±5 digits (45 Hz to 66 Hz)
Position wire as close as possible to jaw opening (see illustration).
AC Voltage: Test Leads
Range
600.0 V 1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1 % ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range
600.0 V
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1 % ±5 digits
mV dc
Range
500.0 mV
Resolution
0.1 mV
Accuracy
1 % ±5 digits
Amps Frequency: Jaw
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % ±5 digits
Trigger Level
5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amps Frequency: Flexible Current Probe
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % ±5 digits
Trigger Level
5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz,≥25 A
Resistance
Range
60.00 kΩ
6000 Ω
600.0 Ω
Resolution
0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60.00 kΩ)
Accuracy
1 % ±5 digits
Capacitance
Range
1000 μF
Resolution
0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy
1 % ±4 digits
Mechanical
Size (L x W x H)
274 mm x 86 mm x 47 mm
Weight (with Batteries)
463 g
Jaw Opening
34 mm
Flexible Current Probe Diameter
7.5 mm
Flexible Current Probe Cable Length (head to electronics connector)
1.8 m
Rogowski Coil Length
450 mm
Environmental
Operating Temperature
-10 °C to 50 °C
Storage Temperature
-40 °C to 60 °C
Operating Humidity (without condensation)
Non condensing (<10> ≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C >28 °C or <18>
Ingress Protection
IEC 60529: IP30 (jaw closed)
Operating Altitude
2000 m
Storage Altitude
12 000 m
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)
Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
General
IEC 61010-1: Pollution degree 2
Measurement
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Voltage and current measurements with FieldSense™ technology
The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.
Measure extremely high current with iFlex® probe
Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.
Complete 3-phase measurements in quick, easy steps
Complete 3-phase voltage and current tests in 3 easy steps
Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
Phase rotation auto-calculated and shown on the Fluke Connect software
No more hand-written notes or complicated math.
Easy to see, easy to use with included tools
Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.
Record, analyze, share results with Fluke Connect® software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.
What's Included?
Fluke 377 FC Non-Contact Voltage True-RMS AC/DC Clamp Meter
TL224 Test Leads
TP175 TwistGuard™ Test Probes
AC285 black grounding clip (1 only)
i2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)
TPAK ToolPak™ Magnetic Meter Hanger
Premium carrying case
Quick reference guide
Specifications
General specifications
General Maximum Voltage between any Terminal and Earth Ground
1000 V
Battery
Type
2 AA IEC LR6 alkaline
Life
200 hour
Display
Dual readout
Automatic Power Off
20 minutes
Electrical
AC Current: Jaw
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % ±5 digits (10 Hz to 100 Hz)
2.5 % ±5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)
3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range
2500 A
Resolution
1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy
3 % ±5 digits (5 Hz to 500 Hz)
Crest Factor (50/60Hz)
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
Position Sensitivity
Distance from Optimum
i2500-10 Flex
i2500-18 Flex
Error
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
± 0.5 %
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
± 1.0 %
C
1.4 in (35.6 mm)
2.5 in (63.5 mm)
± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % ±5 digits1
[1]When using the ZERO function to compensate for offsets
AC Voltage: Field Sense
Range
1000 V
Resolution
1 V (≤1000V)
Accuracy
≤4/0 AWG
3 % ±5 digits (45 Hz to 66 Hz)
≥4/0 AWG
5 % ±5 digits (45 Hz to 66 Hz)
Position wire as close as possible to jaw opening (see illustration).
AC Voltage: Test Leads
Range
600.0 V 1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1 % ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range
600.0 V
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1 % ±5 digits
mV dc
Range
500.0 mV
Resolution
0.1 mV
Accuracy
1 % ±5 digits
Amps Frequency: Jaw
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % ±5 digits
Trigger Level
5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amps Frequency: Flexible Current Probe
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5 % ±5 digits
Trigger Level
5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz,≥25 A
Resistance
Range
60.00 kΩ
6000 Ω
600.0 Ω
Resolution
0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60.00 kΩ)
Accuracy
1 % ±5 digits
Capacitance
Range
1000 μF
Resolution
0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy
1 % ±4 digits
Mechanical
Size (L x W x H)
274 mm x 86 mm x 47 mm
Weight (with Batteries)
463 g
Jaw Opening
34 mm
Flexible Current Probe Diameter
7.5 mm
Flexible Current Probe Cable Length (head to electronics connector)
1.8 m
Rogowski Coil Length
450 mm
Environmental
Operating Temperature
-10 °C to 50 °C
Storage Temperature
-40 °C to 60 °C
Operating Humidity (without condensation)
Non condensing (<10> ≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C >28 °C or <18>
Ingress Protection
IEC 60529: IP30 (jaw closed)
Operating Altitude
2000 m
Storage Altitude
12 000 m
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)
Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
General
IEC 61010-1: Pollution degree 2
Measurement
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site.
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.
Part of the Fluke Connect wireless family
As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.
The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.
A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
Offers 200 µA DC current measurements to measure flame rod
Extends resistance range to measure thermistors up to 60kΩ
Captures flue gas temperature
Measures start and run motor capacitors
Measures variable frequency drive performance
Ergonomic design fits in your hand and can be used while wearing personal protective equipment
Large, easy-to-read backlit display improves readings in low light settings
Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warrant
Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
Measures AC current to 600 A and AC and DC voltage to 600 V
Measures capacitance to 1000 µF and DC current to 200 µA
Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
Offers True-RMS voltage and current measurements to accurately measure non-linear signals
Measures resistance to 60 kΩ
Offers Min/Max recording to capture variations automatically
Runs on two AA alkaline batteries
What's Included?
TL75 test leads (1 pair)
80BK integrated DMM temperature probe (1)
AA alkaline batteries (2)
Soft carrying case
User’s manual
Statement of calibration
Specifications
Function
A ac (via Jaw)
Resolution
0.01/0.1 A
Accuracy
2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range
60.00/600.0 A
Crest Factor (50Hz or 60Hz)
2.5 MIN@220 A
3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
V ac
Resolution
0.1 V
Accuracy
1.5% ±5 digits
Range
600.0 V
V dc
Resolution
0.1 V
Accuracy
1.5% ±5 digits
Range
600.0 V
Ohms
Resolution
0.1/1/10
Accuracy
1% ±5 digits
Range
600/6000/60.00 kΩ
Capacitance
Resolution
0.1/1 µF
Accuracy
1% ±4 digits
Range
100.0/1000 µF
µA
Resolution
0.1 µA
Accuracy
1% ±5 digits
Range
200 µA
Contact temperature
Resolution
0.1 C/F
Accuracy
1% ±8 digits
Range
-40 to 400 °C (-40 °F to 752 °F)
Continuity beeper
Beeper volume
75 dBA nom. 15 cm. from case front
On threshold
<=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground
1000 V
Battery type
2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature
Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidity
Non condensing (< 10>
Altitude
Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions
230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only)
419 g (15 oz)
Safety
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating
IEC 60529: IP30, non-operating
Radio Frequency Certification
FCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients
Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.
Use wireless connectivity to keep a safe distance
The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.
Versatile feature set
With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.
Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect® for viewing at a safer distance
Performs AC and DC current measurements to 600 A, and AC and DC voltage measurements to 1000 V
Measures AC current to 2500 A AC with optional iFlex flexible current probe
Measures resistance to 6000 Ω with continuity detection
Other useful capabilities:
Compatible with optional TPAK magnetic hanging strap
Comes with soft carrying case, batteries, and three-year warranty
Measures capacitance to 1000 µF
Features CAT III 1000 V, CAT IV 600 V safety rating
Provides True-RMS voltage and current measurements to accurately measure non-linear signals
Includes Min/Max/Avg and inrush recording to capture variations automatically
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
600.0 A
Resolution
0.1 A
Accuracy
2% ±5 digits
AC Voltage
Range
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1% ±5 digits
mV dc
Range
500.0 mV
Resolution
0.1 mV
Accuracy
1% ±5 digits
Resistance
Range
6000 Ω
Resolution
0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
Accuracy
1% ±5 digits
Capacitance
Range
1000 μF
Resolution
0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy
1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground
1000 V
Batteries
2 AA, NEDA 15A, IEC LR6
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity –
non-condensing (< 10>
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude
3000 m
Storage altitude
12,000 m
Size (L x W x H)
249 x 85 x 45 mm
Weight
395 g
Jaw opening
34 mm
Flexible current probe diameter
7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
Safety
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP rating
IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID
T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Fluke 375 FC True-RMS AC/CD Clamp Meter measures very low voltage and very high resistance
The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect
The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.
Wireless connectivity improves productivity
Using its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLive™ video calls.
Versatile performance
With True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.
Other useful capabilities:
Compatible with optional TPAK magnetic hanging strap
Comes with batteries, soft carrying case, and three-year warranty
Features CAT III 1000 V, CAT IV 600 V safety rating
Measures capacitance to 1000 µF
Includes True-RMS voltage and current measurements to accurately measure non-linear signals
Measures frequency to 500 Hz and resistance to 60 kΩ with continuity detection
Includes Min/Max/Avg and inrush recording to capture variations automatically
Offers 500 mV DC measurement range to interface with other accessories
Runs on two AA alkaline batteries
What's Included?
Soft carrying case
TL75 test leads
Two AA Alkaline batteries
Coated instruction card
Safety information sheet
Specifications
General Specifications
AC Current via Jaw
Range
600.0 A
Resolution
0.1 A
Accuracy
2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)
3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range
2500 A
Resolution
0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy
3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
DC Current
Range
600.0 A
Resolution
0.1 A
Accuracy
2% ±5 digits
AC Voltage
Range
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range
1000 V
Resolution
0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy
1% ±5 digits
mV dc
Range
500.0 mV
Resolution
0.1 mV
Accuracy
1% ±5 digits
Frequency via Jaw
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5% ±5 digits
Trigger level
5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
Frequency via Flexible Current Probe
Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Accuracy
0.5% ±5 digits
Trigger level
5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range
60 kΩ
Resolution
0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy
1% ±5 digits
Capacitance
Range
1000 μF
Resolution
0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy
1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Fluke 373 True RMS AC Clamp Meter does the job for any AC-only current measurement application
Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.
To make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more.
A top performing True-RMS current clamp for AC-only current measurements to 600 A
Measures AC and DC voltage to 600 V
Measures resistance to 6000 Ω with continuity detection
Offers state of the art signal processing to provide stable readings even in noisy electrical environments
Other useful capabilities:
Provides True-RMS voltage and current measurements to accurately measure non-linear signals
Automatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement
Presents readings on a large, easy-to-read backlit display
Features CAT IV 300 V, CAT III 600 V safety ratings
Comes with a soft carrying case and three-year warranty
Runs on two AA alkaline batteries
What's Included?
Coated instruction card
Safety information sheet
Soft carrying case
TL75 test leads
Two AA Alkaline batteries
Specifications
Electrical Specifications
AC Current
Range
600.0 A
Resolution
0.1 A
Accuracy
2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz)
2.5 @ 600 A
AC Voltage
Range
600.0 V
Resolution
0.1 V
Accuracy
1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range
600.0 V
Resolution
0.1 V
Accuracy
1 % ± 5 digits
Resistance
Range
600.0 Ω/6000 Ω
Resolution
0.1 Ω/1 Ω
Accuracy
1 % ± 5 digits
Continuity Beeper
30 Ω
Capacitance
Range
10.0 – 100.0 μF / 1000 μF
Resolution
0.1 μF/1 μF
Accuracy
1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H)
232 mm x 85 mm x 45 mm
Weight
370 g
Environmental Specifications
Operating Temperature
-10 °C to +50 °C
Storage Temp
-40 °C to +60 °C
Operating Humidity
Non condensing (< 10> ≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude
3000 meters
Storage Altitude
12,000 meters
EMI, EMC
Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance
ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
Detect document; record and compare leakage current readings over time as a means of preventing unplanned downtime; and identifying intermittent GFCI and RCD trips; all without taking equipment off line.
True-rms measurements for accuracy when measuring complex; non-sinusoidal waveforms
61 mm jaw opening
Highest resolution of 1 µA; measure up to 60 A
Selectable filter function removes unwanted noise
Max/Min/Average readings and hold function
Forward-facing LED worklight for use in dark wiring cabinets
Backlit display; auto backlight off and auto power off for extended battery life
CAT III 600V safety rating
What's Included?
Leakage Clamp Meter
Soft case
Safety manual
Batteries: 2 AA
Specifications
Electrical Specifications
Measurement function
Alternating current
AC ampere range
3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection
mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution
3 mA⊃1; / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)⊃2;
3 mA – 30 A
1% + 5 digits
60 A
2% + 5 digits
Frequency
40 Hz to 1 kHz
Crest Factor
3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
⊃1;The minimum value is 10 μA rms.
⊃2;Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD)
Digital readout: 3300 count
Display refresh rate
4 times / sec
Maximum conductor diameter
61 mm
Dimensions
257 x 116 x 46 mm
Weight
600 g
Battery
2 AA, IEC LR6, NEDA 15A, alkaline
Battery life
Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down
Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety
IEC 61010-1: Pollution Degree 2
Measurement safety
IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Operating humidity
Non-condensing (<10>
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection class
IEC 60529: IP30 (jaw closed)
Operating altitude
2000 m
Storage altitude
12000 m
Current sensor action category
IEC 61557-13: Class 1, ≤100 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1
Industrial Electromagnetic Environment
CISPR 11
Group 1 Class B
Group 1
Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device’s own internal functions is essential.
Class B
Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A
This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per
Versatile and rugged tools for applications with high currents
Confidently take reliable readings with the True RMS, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter.
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A large backlit display allows for easy visibility in low-lit areas
Use the display hold feature to capture readings even when the display cannot be viewed
Use the low-pass filter to smooth out noisy loads and stabilize readings
What's Included?
C43 soft carrying case
6 AA batteries
TL224 1.5 m silicone rubber test leads
TP2 test probes
AC285 alligator clips
User manual
3 year warranty
Specifications
Electrical Specifications
Current measurement DC and AC 10 Hz to 100 Hz
Range
40 A / 400 A / 2000 A / 1400 AC rms
Resolution
10 mA / 100 mA / 1 A
Accuracy
A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush
0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF
2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON
0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz)
Range
40 A / 400 A / 2000 A / 1400 AC rms
Crest Factor1
2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
UT220 series are 2000A AC/DC digitalclamp meters. This series ensures stable performance, safety, and reliability for measuring up to 2000A AC (and DC for UT221) current. It is designed with over-load protection for all ranges, perfect for all professionals measuring currents up to 2000A (2500A for UT222).
Specifications
Range
UT221
AC current (A)
2000A
±(2.5%+5)
DC current (A)
2000A
±(2.5%+5)
AC voltage (V)
750V
±(1.2%+5)
DC voltage (V)
1000V
±(0.8%+1)
Resistance (Ω)
66MΩ
±(1%+2)
Frequency (Hz)
20MHz
±(0.1%+3)
Features
Display count
6000
Auto range/Diode
√
Jaw opening
63mm
True RMS (AC voltage/AC current)
√
Duty cycle
10%~90%
√
Continuity buzzer
√
Low pass filter
√
Inrush current
AC current
√
Relative mode
√
Data hold/MAX
√
MIN/I-OUT function
√
Analog bar graph
66
Full icon display
√
Low battery indication
√
Input impedance
≥10MΩ
√
General Characterisitics
Power
9V battery (6F22)
Display
43mm x 30mm
Product color
Red and grey
Product net weight
726g
Product size
298mm x 107mm x 47mm
Standard accessories
Test leads, output cable
Standard individual packing
Gift box, tool box, English manual
Standard quantity per carton
5pcs
Standard carton measurement
510mm x 375mm x 320mm
Standard carton gross weight
12.1kg
Cash on delivery available
Returns not allowed
Join Our Newsletter Now
Get E-mail updates about our latest shop and special offers.
Address: GooXoom.com