Features
- 600 V Cat III safety rating
- 50% bigger display with bright white backlight
- Voltage, resistance, continuity, capacitance
- Input terminal for ac and dc current measurements to 10 A current
- Diode test, data hold
What's Included?
- TL75 test leads with two caps
- 2 AA batteries
- User’s manual
Specifications
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function |
Range |
Resolution |
Accuracy |
AC volts
(40 Hz to 500Hz)1 |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
1.0% + 3 |
DC volts |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
0.5% + 3 |
AC millivolts |
400.0 mV |
0.1 mV |
3.0% + 3 |
DC millivolts |
400.0 mV |
0.1 mV |
1.0% + 10 |
Diode test2 |
2.000 V |
0.001 V |
10% |
Resistance
(Ohms) |
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ |
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ |
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3 |
Capacitance |
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF |
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF |
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5 |
AC current μA
(40 Hz to 400 Hz) |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5% + 3 |
AC current mA
(40 Hz to 400 Hz) |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5% + 3 |
AC current A
(40 Hz to 400 Hz) |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5% + 3 |
DC current μA |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5% + 3 |
DC current mA |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5% + 3 |
DC current A |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5% + 3 |
Backlight |
Yes |
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0> 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). |
Function |
Overload protection |
Input impedance (Nominal) |
Common mode rejection ratio |
Normal mode rejection ratio |
AC volts |
1000 V 1 |
>10 MΩ <100> |
>60 dB at dc,
50 Hz or 60 Hz |
– |
AC millivolts |
400 mV |
>1MΩ, <100> |
>80 dB at 50 Hz or 60 Hz |
– |
DC volts |
1000 V 1 |
>10 MΩ <100> |
>100 dB at dc,
50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
DC millivolts |
400 mV |
>1MΩ, <100> |
>80 dB at 50 Hz or 60 Hz |
– |
1 106 V Hz Max |
General specifications |
Maximum voltage between any terminal and earth ground |
1000 V |
Display (LCD) |
4000 counts, updates 3/sec |
Battery type |
2 AA, NEDA 15A, IEC LR6 |
Battery life |
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) |
Temperature |
Operating |
0 °C to 40 °C |
Storage |
-30 °C to 60 °C |
Relative humidity |
Operating humidity |
Non-condensing (<10> ≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C |
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C |
Altitude |
Operating |
2000 m |
Storage |
12,000 m |
Temperature coefficient |
0.1 X (specified accuracy) /°C (<18>28 °C) |
Fuse protection for current inputs |
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only. |
Size (H x W x L) |
183 x 91 x 49.5 mm |
Weight |
455 g |
IP rating |
IP 40 |
Safety |
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 |
Electromagnetic environment |
IEC 61326-1: Portable |
Electromagnetic compatibility |
Applies to use in Korea only |
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes. |