A digital multimeter is a device that measures two or more electrical quantities, primarily voltage (volts), current (amps), and resistance (ohms) (ohms). For technicians in the electrical and electronic industries, it is a typical diagnostic tool.
An electronic measuring device that combines multiple measurement operations into a single unit is called a digital multimeter (DMM). It has the ability to measure resistance, voltage (both AC and DC), and current (both AC and DC).
Display: Digital multimeters are easy to read because of their numeric display, which presents measurements as digits. For more dynamic readings, some models additionally come with an analog display or bar graph.
Voltage: Calculates the difference in electrical potential between two places. It has the ability to monitor voltages of both direct current (DC) and alternating current (AC).
Current: Calculates how much electric charge is moving through a circuit. It can measure both AC and DC, just like voltage.
Resistance: The amount that an object opposes an electric current's flow is measured.
The Fluke 179 True-RMS DMM is the industry-standard troubleshooting tool for electrical and electronic systems.
With its precision, reliability, and ease of use, the Fluke 179 is the preferred solution for professional technicians around the world. It includes the features you need to troubleshoot and repair electrical and electronic systems, plus a backlit digital display, analog bar graph, and built-in temperature measurements.
Works When You Need It, Where You Need It
You can trust the rugged reliable Fluke 179 to get the job done in all of the messy, loud, high energy, and high altitude places you work. Whether you need a multimeter for industrial troubleshooting or electrical and electronic system installation or maintenance, the Fluke 179 with its true-RMS capabilities can do the job. It is independently tested for safe use in CAT III 1000 V, CAT IV 600 V environments and backed by a lifetime warranty.
Just One of Fluke’s Trusted Tools
Fluke builds the most trusted tools in the world, which means more than just the Fluke 179. If you work with HVAC equipment, work in the electrical installer’s and repairman’s world or need a small meter for small spaces, check out the full family of Fluke digital multimeters.
Other useful features:
A full-featured, precision multimeter for troubleshooting electrical and electronic systems
Delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
Includes a built-in thermometer to measure temperature without having to carry a separate instrument
Safety rated CAT III 1000 V, CAT IV 600 V
Comes with a lifetime warranty
Allows closed-case calibration through front panel
Includes ergonomic case with integrated protective holster
What's Included?
80BK Temperature Probe
Installed 9V battery
Test leads
Users manual
Specifications
Specifications
Voltage DC
Accuracy1
±(0.09% + 2)
Max. resolution
0.1 mV
Maximum
1000 V
Voltage AC
Accuracy1
±(1.0% + 3)
Max. resolution
0.1 mV
Maximum
1000 V
Current DC
Accuracy1
±(1.0% + 3)
Max. resolution
0.01 mA
Maximum
10 A
Current AC
Accuracy1
±(1.5% + 3)
Max. resolution
0.01 mA
Maximum
10 A
Resistance
Accuracy1
±(0.9% + 1)
Max. resolution
0.1 Ω
Maximum
50 MΩ
Capacitance
Accuracy1
±(1.2% + 2)
Max. resolution
1 nF
Maximum
10,000 µF
Frequency
Accuracy1
±(0.1% + 1)
Max. resolution
0.01 Hz
Maximum
100 kHz
Temperature
Accuracy1
±(1.0% + 10)
Max. resolution
0.1°C
Range
-40°C / 400°C
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature
-10°C to +50°C
Storage temperature
-30°C to +60°C
Humidity (without condensation)
0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category
EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IV
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Typically, open circuit test voltage is 2.0 V and short circuit current is <0>
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC Volts
600 V 1
>10 MΩ <100>
>60 dB at dc,
50 Hz or 60 Hz
−
AC Millivolts
600 mV
>1M, <100>
>80 dB at 50 Hz or 60 Hz
−
DC Volts
600 V 1
>10 MΩ <100>
>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
6 x 105 V Hz Max
For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground
600 V
Display (LCD)
6000 counts, updates 3/sec
Battery Type
2 AAA, NEDA 24A, IEC LR03
Battery Life
200 hours minimum
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative Humidity
Operating Humidity
Non-condensing when <10> ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range
≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature Coefficient
0.1 X (specified accuracy) /°C (<18>28 °C)
Fuse Protection for Current Inputs
11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL)
142 mm x 69 mm x 28mm
Weight
200 g
IP Rating
IEC 60529: IP 40
Safety
IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment
IEC 61326-1: Portable
Electromagnetic Compatibility
Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
Fluke 114 digital multimeter is the ideal choice for go/no-go testing
Designed for easy one-handed operation, the compact Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. And you can use the LoZ function to identify so-called ghost voltage and prevent false readings.
The Fluke 114 displays True-RMS voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. A large white LED backlight aids work in poorly lit areas. And its easy-open battery access door makes battery changes easy.
A great choice for everyday troubleshooting, the Fluke 114 Electrical Multimeter is CAT III 600 V safety rated and is a compact True-RMS meter.
Fluke 114 multimeters are independently tested for safe use in CAT III 600V environments
Other useful features:
Features a compact ergonomic design for one-handed operation
Comes with an holster with probe holders for easy storage
Features manual and automatic ranging
Safety rates CAT III 600 V
Fits into optional ToolPak™ magnetic hanger for hands-free operation
FEATURES
Ideal Digital Multimeter for “go/no-go” testing
Features AutoVolt automatic AC/DC voltage selection
Includes low input impedance to help prevent false readings due to ghost voltage
Presents a large white LED backlight for working in poorly lit areas
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average with elapsed time to record signal fluctuations
What's Included?
Holster
Installed 9 V battery
Test leads
User manual
Specifications
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001
V60.00 V / 0.01
V600.00 V / 0.1 V
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution
600.0 V / 0.1 V
Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001
V60.00 V / 0.01
V600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20> 250 Ω detects opens or shorts of
500 μs or longer.
1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
The Fluke 115 is the compact, general purpose troubleshooting tool for field service technicians
For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments.
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Other useful features:
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average with elapsed time to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
What's Included?
Holster
Installed 9 V battery
4 mm silicone test lead sets
User manual
Specifications
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20> 250 Ω detects opens or shorts of
500 μs or longer.
Ohms
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy
0.9% + 1
Range/resolution
40.00 MΩ / 0.01 MΩ
Accuracy
5% + 2
Diode test
Range/resolution
2.00 V / 0.001 V
Accuracy
0.9% + 2
Capacitance
Range/resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy
1.9% + 2
Range/resolution
> 1000 μF
Accuracy
5% + 20%
Lo-Z capacitance
Range
1 nF to 500 μF
Accuracy
10% + 2 typical
AC amps True RMS
Range/resolution
6.000 A / 0.001 A
(45 Hz to 500Hz)
10.00 A / 0.01 A
Accuracy
1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/resolution
6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy
1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2
Range/resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50 kHz / 0.01 kHz
Accuracy
0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment
The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.
Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
Digital multimeter designed specifically for HVAC professionals
Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
Provides microamps to test flame sensors
Features low input impedance to helps prevent false readings due to ghost voltage
Presents a large white LED backlight for working in poorly lit areas
Other useful features:
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
What's Included?
4 mm silicone test lead set
80BK Integrated Temperature probe
Holster
Installed 9 V battery
User manual
Specifications
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy
±([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution
600.0 V / 0.1 V
Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20> 250 Ω detects opens or shorts of
500 μs or longer.
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
The Fluke 117 Digital Multi meter includes integrated non-contact voltage detection to help get the job done faster
Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
Engineered and Tested with Your Safety on the Job in Mind
We test Fluke 117 multimeters for safe use in CAT III 600 V environments and we have designed in several features to make it easier and faster for you to get the measurements you need, including:
Measures 10 A (20 A overload for 30-seconds)
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average to record signal fluctuations
Comes with an holster with probe holders for easy storage
Features compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
A large white LED backlight to improve measurement visibility in poorly lit areas
VoltAlert™ technology for fast, go/no go non-contact voltage detection
AutoVolt and low input impedance modes to provide faster, more accurate readings
What's Included?
Fluke 117 Electrician’s Digital Multimeter with Non-Contact Voltage
4 mm silicone test lead set
Holster
User manual
Specifications
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to +50°C
Storage temperature
-40°C to +60°C
Battery type
9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy
±([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution
600.0 V / 0.1 V
Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts⊃1; True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts⊃1; True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20> 250 Ω detects opens or shorts of
500 μs or longer.
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
What's Included?
TL75 test leads with two caps
2 AA batteries
User’s manual
Specifications
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0> 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function
Overload protection
Input impedance (Nominal)
Common mode rejection ratio
Normal mode rejection ratio
AC volts
1000 V 1
>10 MΩ <100>
>60 dB at dc,
50 Hz or 60 Hz
–
AC millivolts
400 mV
>1MΩ, <100>
>80 dB at 50 Hz or 60 Hz
–
DC volts
1000 V 1
>10 MΩ <100>
>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts
400 mV
>1MΩ, <100>
>80 dB at 50 Hz or 60 Hz
–
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground
1000 V
Display (LCD)
4000 counts, updates 3/sec
Battery type
2 AA, NEDA 15A, IEC LR6
Battery life
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative humidity
Operating humidity
Non-condensing (<10> ≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18>28 °C)
Fuse protection for current inputs
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)
183 x 91 x 49.5 mm
Weight
455 g
IP rating
IP 40
Safety
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment
IEC 61326-1: Portable
Electromagnetic compatibility
Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.
Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
Fluke quality is always within your reach
Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.
What's Included?
TPAK Meter Hanging Kit
TL175 Twist Guardª Test Leads
Specifications
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0> 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.
Function
Overload protection
Input impedance (Nominal)
Common mode rejection ratio
Normal mode rejection ratio
AC volts
1000 V 1
>10 MΩ <100>
>60 dB at dc,
50 Hz or 60 Hz
–
AC millivolts
400 mV
>1MΩ, <100>
>80 dB at 50 Hz or 60 Hz
–
DC volts
1000 V 1
>10 MΩ <100>
>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts
400 mV
>1MΩ, <100>
>80 dB at 50 Hz or 60 Hz
–
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground
1000 V
Display (LCD)
4000 counts, updates 3/sec
Battery type
2 AA, NEDA 15A, IEC LR6
Battery life
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative humidity
Operating humidity
Non-condensing (<10> ≤90% RH at 10 °C to 30 °C
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C
≤70% RH at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature coefficient
0.1 X (specified accuracy) /°C (<18>28 °C)
Fuse protection for current inputs
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)
183 x 91 x 49.5 mm
Weight
455 g
IP rating
IP 40
Safety
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment
IEC 61326-1: Portable
Electromagnetic compatibility
Applies to use in Korea only
Class A equipment (industrial broadcasting and communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.
Fluke 175 is the baseline for industrial measurements
The Fluke 175 True RMS Digital Multimeter delivers the baseline general purpose features required by professional technicians around the world. You can find problems fast with all the basic troubleshooting measurements such as frequency, capacitance, resistance, continuity, and diode. And Display Hold and Auto Hold will help you capture significant events.
Safety rated for industrial use
All inputs on the 175 are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending. You can rely on the Fluke 175 for accurate, true-RMS readings through years of reliable service.
Need More Accuracy or Temperature Measurements?
If you need a higher degree of accuracy or contact temperature measurements click here see Fluke 177 and Fluke 179 True RMS Digital Multimeters
Provides the baseline multimeter features you need for troubleshooting and repairing electrical and electronic systems
Delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
Other useful features:
Safety rated CAT III 1000 V, CAT IV 600 V
Comes with a lifetime warranty
Allows closed-case calibration through front panel
Includes ergonomic case with integrated protective holster
What's Included?
Installed 9V battery
Test leads
Users manual
Specifications
Specifications
Voltage DC
Accuracy1
±(0.15% + 2)
Max. resolution
0.1 mV
Maximum
1000 V
Voltage AC
Accuracy1
±(1.0% + 3)
Max. resolution
0.1 mV
Maximum
1000 V
Current DC
Accuracy1
±(1.0% + 3)
Max. resolution
0.01 mA
Maximum
10 A
Current AC
Accuracy1
±(1.5% + 3)
Max. resolution
0.01 mA
Maximum
10 A
Resistance
Accuracy1
±(0.9% + 1)
Max. resolution
0.1 Ω
Maximum
50 MΩ
Capacitance
Accuracy1
±(1.2% + 2)
Max. resolution
1 nF
Maximum
10,000 µF
Frequency
Accuracy1
±(0.1% + 1)
Max. resolution
0.01 Hz
Maximum
100 kHz
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature
-10°C to +50°C
Storage temperature
-30°C to +60°C
Humidity (without condensation)
0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category
EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IV
Agency approvals
UL, CSA, TÜV listed and VDE Pending
Mechanical and General Specifications
Size
43 x 90 x 185 mm
Weight
420 g
Warranty
Lifetime
Battery life
Alkaline ~200 hours typical, without backlight
Cash on delivery available
Returns not allowed
Join Our Newsletter Now
Get E-mail updates about our latest shop and special offers.
Address: GooXoom.com
Salah Al Din Street
Deira, Dubai
United Arab Emirates