Secure transfer through an optional Time switch programs can only be transferred from the app to the time switch when the Bluetooth OBELISK top3 is inserted into the time switch for maximum manipulation security.
Top2 is completely compatible
Spring terminals with DuoFix
Wire diameter: 0.5 mm2 to 2.5 mm2 for each conductor, with or without wire end sleeves.
Designed to limit the number of attempts an engine has to start before providing an alarm
Selectable number of attempts (2-8)
Multi-voltage (12 –48VAC/DC)
Single time range (1 – 60s)
2 x SPDT Relay outputs
17.5mm wide, DIN Rail mount
UL Listed
The timer is offered with two separate relays. When power is applied, the first relay (Attempts) will energise for the set “on” time delay period, then de-energise for the set “off” time delay period. This is classed as the “first attempt”. The same relay will continue to cycle on and off for the “number of attempts” set on the adjustment. If all the attempts are allowed to run, at the end of the last “on” time delay period, the first relay will de-energise and the second relay (Alarm) will energise and remain in this state. Power must be removed and re-applied to restart the function over again.
When power is applied, the output relay remains de-energised for the set time delay period. After the delay has elapsed, the contacts “break” for the set Dwell time, then changeover to the energised state. Power must be removed and re-applied to restart the function over again.
SPECIFICATION:
Timing function: Star/Delta Start
Supply voltage: 12 – 230VAC/DC +/-15% (-10% if AC)
The output relay energises as soon as power is applied. When power is removed, the set time delay period commences and the relay will remain energised for this period. After the delay has elapsed, the relay de-energises. Power must be removed and re-applied to restart the function over again.