Roll
AED 848.40
AED 848.40
Key Specifications
Manufacturer: Belden
Model: 5200UE, 2 conductor, 16 AWG, bare copper (BC) stranded (19 × 29) — unshielded.
Insulation: Polyolefin (PP) with nominal thickness 0.008 in (0.20 mm). Colour-coded: black & red.
Jacket: PVC (Polyvinyl Chloride), nominal thickness 0.017 in (0.43 mm). Overall cable diameter approx 0.180 in (4.57 mm). Ripcord included.
Electrical:
Conductor DCR: ~4.2 Ω per 1000 ft.
Capacitance (cond-to-cond): ~23 pF/ft (≈75 pF/m)
Inductance: ~0.14 µH/ft (≈0.46 µH/m)
Max recommended current: 6.25 A per conductor at 25 °C ambient.
Voltage rating: 300 V RMS (CMR)
Temperature rating: Operating range –20 °C to +75 °C; UL rating +75 °C.
Jacket/Finish: Designed for indoor riser (CMR) environments. Not plenum rated.
Variants/Colors: Several jacket colours available (black, grey, white, red, brown etc) depending on part number.
Cash on delivery available
Returns allowed
Roll
AED 441.00
AED 441.00
Key Specifications
Manufacturer: Belden
Model: 5500FE — 2 conductors of 22 AWG, bare copper (BC) stranded conductor (7×30)
Insulation: Polypropylene (PP) insulation, nominal thickness ~0.008 in (0.20 mm)
Shielding: “Beldfoil®” aluminium/polyester foil tape, 100% coverage. Drainwire included (24 AWG tinned copper)
Jacket: PVC (Polyvinyl Chloride), with rip-cord, nominal jacket wall thickness ~0.017 in (0.43 mm). Overall nominal diameter ~0.126 in (3.20 mm)
Electrical:
Conductor DCR (DC resistance): ~16.9 Ω per 1,000 ft
Capacitance conductor-to-conductor: ~34.5 pF/ft (~113 pF/m)
Capacitance conductor-to shield (other): ~62 pF/ft (~200 pF/m)
Max recommended current: 6 Amps per conductor at 25 °C
Voltage rating: 300 V RMS
Temperature rating: UL rating +75 °C; operating range −20 °C to +75 °C
Environment/Standards: Indoor use, riser-CMR rated (not plenum). Meets UL 1666 (riser) / FT4 / IEC 60332-1-2. Complies with NEC Article 800
Cash on delivery available
Returns allowed
Roll
AED 918.75
AED 918.75
Key Specifications
Conductors: 2 conductors, 16 AWG , stranded (19 × 29) bare copper.
Insulation: Polypropylene (PP) insulation around each conductor.
Shielding: 100% foil shield (Beldfoil®) with a drain wire (24 AWG tinned copper) for the overall shield.
Jacket: PVC outer jacket with ripcord; nominal overall diameter ~0.184 in (≈ 4.67 mm).
Rated voltage: 300 V (UL).
Operating temperature: –20 °C to +75 °C; UL temperature rating 75 °C.
Cash on delivery available
Returns allowed
Roll
AED 715.50
AED 715.50
Key Specifications
Two (2) conductors, each 18 AWG (stranded 7×26) bare copper (BC) material
Insulation: polypropylene (PP) around each conductor (nominal 0.009 in / 0.23 mm wall thickness; nominal insulation diameter ~0.062 in / 1.6 mm) in the black and red colour pair
Shield: 100% coverage bi-laminate tape (Aluminium + Poly) known as Beldfoil® shield, plus a 24 AWG (7 × 32) tinned copper (TC) drain wire
Outer jacket: PVC (Polyvinyl Chloride) jacket, nominal wall ~0.017 in (0.43 mm), overall diameter ~0.162 in / 4.11 mm. The jacket includes a rip-cord for easier stripping
Electrical / Mechanical:
Conductor DCR (direct current resistance): ~6.5 Ω per 1000 ft
Capacitance: ~53 pF/ft conductor-to-conductor; ~95.5 pF/ft conductor-to-shield/other conductor
Inductance: ~0.145 µH/ft
Max Recommended Current: approx. 5 A per conductor at 25 °C
Voltage rating: 300 V (RMS) for the jacketed cable
Temperature rating: Operating range –20 °C to +75 °C; UL temperature rating 75 °C
Flame / Riser rating: The cable is a riser‐rated (CMR) indoor cable, suitable for vertical riser shafts and indoor routing
Cash on delivery available
Returns allowed
Roll
AED 477.75
AED 477.75
Key Specifications
Category: Category 6 (250 MHz) horizontal/ building-backbone cable.
Conductors: 4 twisted pairs, each conductor 23 AWG , solid bare copper.
Insulation: Polyethylene (PE) per conductor.
Jacket: PVC outer jacket (indoor version) with nominal diameter ~5.4 mm.
Shielding: Unshielded twisted pair (U/UTP) — no overall foil or braid.
Impedance: Nominal ~100 Ω.
Ratings: Designed for indoor premise horizontal/back-bone use; CPR Euroclass rating “Eca”.
Cash on delivery available
Returns allowed
Roll
AED 477.75
AED 477.75
Key Specifications
Category: Category 6 (250 MHz) horizontal / building-backbone cable.
Construction: 4 twisted pairs, each conductor solid bare copper 23 AWG.
Insulation: Polyethylene (PE) insulation around each conductor.
Jacket: LSZH / Low Smoke Zero Halogen jacket (for “ENH” version) — i.e., Low Fire Hazard rated.
Unshielded cable: U/UTP (unshielded twisted pair overall; no overall shield).
Nominal impedance: ~100 Ω.
Cash on delivery available
Returns allowed
Roll
AED 730.34
AED 730.34
Key Specifications
Conductors: 2 conductors (one pair) of 22 AWG stranded (7 × 30) tinned copper.
Insulation: Polyethylene (PE) around each conductor.
Shield: 100% overall foil (Beldfoil®) tape shield with a drain wire of 22 AWG tinned copper.
Jacket: PVC outer jacket (nominal diameter ~0.175 in / ~4.45 mm) for standard version.
Voltage rating: 300 V (CM classification) for indoor use.
Temperature rating: Operating range –20 °C to +60 °C in many specs.
Electrical: Nominal conductor DCR about 18.2 Ω/1000 ft. Capacitance approx. 24 pF/ft (core-to-core) and 47 pF/ft (core + shield). Characteristic impedance ~64 Ω.
Mechanical: Minimum bend radius ~1.8 in (46 mm) roughly.
Suitable applications: low-voltage analog signals (4-20 mA, 0-10 V), line level audio, digital control (24 V) etc.
Cash on delivery available
Returns allowed
Roll
AED 964.95
AED 964.95
Key Specifications
Conductors: 2 (one pair) of 18 AWG (16 × 30) tinned copper.
Insulation: Polyethylene (PE) on each conductor.
Shield: 100% overall foil (Beldfoil®) shield + drain wire (20 AWG) for the pair.
Jacket: PVC outer jacket. Overall nominal diameter ~0.222 in (≈ 5.64 mm).
Rated voltage: 300 V (UL, CM classification)
Operating temperature: –20 °C to +60 °C in many specs.
Applications: Audio, control, instrumentation; line-level audio or analog signal routing.
Electrical characteristics: e.g., about 7.06 Ω per 1000 ft conductor resistance; capacitance ~27.2 pF/ft; inductance ~0.18 µH/ft.
Cash on delivery available
Returns allowed
Roll
AED 593.60
AED 593.60
Key Specifications
Conductors: 2 conductors, each 18 AWG (7×26 strands bare copper)
Insulation: Polyolefin (PO) – nominal thickness 0.009 in (0.23 mm) around each conductor.
Jacket: PVC jacket with ripcord for easy removal. Nominal diameter ~ 0.158 in (4.01 mm)
Voltage rating: 300 V (UL rating)
DC Resistance (DCR) of conductor: ~ 6.5 Ω per 1000 ft (≈ 21.3 Ω per km)
Capacitance: ~ 21.5 pF/ft (70.5 pF/m) conductor‑to‑conductor.
Inductance: ~ 0.145 µH/ft (0.476 µH/m)
Max current per conductor: ~ 5 Amps @25 °C in free air for the application.
Temperature rating: -20 °C to +75 °C operating.
Minimum bend radius: ~ 1.6 in (41 mm) both stationary & during installation.
Jacket weight: ~ 15 lbs per 1000 ft (~22 kg per km)
Cash on delivery available
Returns allowed
Roll
AED 1,281.00
AED 1,281.00
Key Specifications
Conductors: 2 (1 pair) of 16 AWG, stranded tinned copper (19 × 29)
Insulation: PVC (Polyvinyl Chloride) around each conductor.
Jacket: PVC outer jacket (in standard version) with overall nominal diameter ~ 0.274 in (≈ 6.96 mm).
Rated for: Up to 300 V (UL rating) and suitable for line-level audio, low voltage analog signals, speaker runs, etc.
Operating temperature: –20 °C to +80 °C in many specs.
Unshielded (no additional shield layer) in the standard version.
Cash on delivery available
Returns allowed