Features
Product overview: Fluke 114 Electrical Multimeter
Fluke 114 digital multimeter is the ideal choice for go/no-go testing
Designed for easy one-handed operation, the compact Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. And you can use the LoZ function to identify so-called ghost voltage and prevent false readings.
The Fluke 114 displays True-RMS voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. A large white LED backlight aids work in poorly lit areas. And its easy-open battery access door makes battery changes easy.
A great choice for everyday troubleshooting, the Fluke 114 Electrical Multimeter is CAT III 600 V safety rated and is a compact True-RMS meter.
Fluke 114 multimeters are independently tested for safe use in CAT III 600V environments
Other useful features:
- Features a compact ergonomic design for one-handed operation
- Comes with an holster with probe holders for easy storage
- Features manual and automatic ranging
- Safety rates CAT III 600 V
- Fits into optional ToolPak™ magnetic hanger for hands-free operation
FEATURES
- Ideal Digital Multimeter for “go/no-go” testing
- Features AutoVolt automatic AC/DC voltage selection
- Includes low input impedance to help prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average with elapsed time to record signal fluctuations
What's Included?
- Holster
- Installed 9 V battery
- Test leads
- User manual
Specifications
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10°C to + 50°C |
Storage temperature |
-40°C to + 60°C |
Battery type |
9 volt Alkaline, NEDA 1604A / IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy specifications |
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/resolution |
6.000 V / 0.001
V60.00 V / 0.01
V600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz) |
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz) |
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001
V60.00 V / 0.01
V600.0 V / 0.1 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz) |
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20> 250 Ω detects opens or shorts of
500 μs or longer. |
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9% + 1 |
Range/resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5% + 2 |
1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight |
550 g |
Warranty |