Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
Item Code: AMSG-2589
Share :
Categories :
Clamp Meter
Cash on delivery available
Return allowed
Sort By:
SlNo
Item code
Product details
Unit
QTY
Unit price
T. price
Action
Features
Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
The large backlight display facilitates readings in dark environments
Current frequency measurement
Precision down to 0.01A and 0.1V
1000A/600A AC/DC current measurement (319/317)
600V AC/DC voltage measurement
4000 Ohms resistance measurement
Continuity beeper
Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
One year warranty
What's Included?
Test Leads
Soft Carrying Case
Three AAA batteries (Installed)
317/319 User Manual
Specifications
General specifications
Digital display
6000 count resolution
Low battery Indication
Displays a signal when the batteries are below their required voltage
Power source
Three AAA IEC LR03 batteries
Clamp opening size
1.45 in (37 mm)
Jaw diameter
1.45 in (37 mm)
Dimensions (L x W x H)
6.39 x 2.29 x 1.20 in
(162.4 x 58.25 x 30.5 mm)
Weight
Approximately 13.5 oz (384 g) (batteries included)
Auto range
Available in Ohms
Safety
CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III
317 Electrical specifications
Current AC
Range
40.00 A, 600.0 A
Resolution
0.01 A, 0.1 A
Accuracy
1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600 A}
2.5% ±5 digit (60-500 Hz) {600 A}
Crest Factor add 2% into spec for CF > 2
3.0 Max @ 500 A, 2.5 Max @ 600 A
AC response
rms
Current DC
Range
40.00 A, 600.0 A
Resolution
0.01 A, 0.1 A
Accuracy
1.6% ±6 digit (40 A)
1.5% ±5 digit (600 A)
Voltage AC
Range
600.0 V
Resolution
0.1 V
Accuracy
1.5% ±5 digit (20-500Hz)
AC response
rms
Voltage DC
Range
600.0 V
Resolution
0.1 V
Accuracy
1% ±4 digit
Resistance
Range
400.0 Ω, 4000 Ω
Resolution
0.1 Ω, 1 Ω
Accuracy
1% ±5 digit
Continuity
≤ 30 Ω
Inrush
Integration time
N/A
Frequency
Range
N/A
Accuracy
N/A
Trigger Level
N/A
319 Electrical specifications
Current AC
Range
40.00 A, 600.0 A, 1000 A
Resolution
0.01 A, 0.1 A, 1 A
Accuracy
1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response
rms
Current DC
Range
40.00 A, 600.0 A, 1000 A
Resolution
0.01 A, 0.1 A, 1 A
Accuracy
1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage AC
Range
600.0 V
Resolution
0.1 V
Accuracy
1.5% ±5 digit (20-500Hz)
AC response
rms
Voltage DC
Range
600.0 V
Resolution
0.1 V
Accuracy
1% ±4 digit
Resistance
Range
400.0 Ω
4000 Ω
Resolution
0.1 Ω
1 Ω
Accuracy
1% ±5 digit
Continuity
≤ 30 Ω
Inrush
Integration time
100 ms
Frequency
Range
5.0 – 500.0 Hz
Accuracy
0.5% ±5 digit
Trigger Level
10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
Environmental specifications
Operating temperature
14°F to 122°F (-10 °C to 50 °C)
Storage temperature
-40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity
Non-condensing (< 50>
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)
Operating altitude
1 mile (2000 meters) above mean sea level
Storage altitude
7 miles (12,000 meters) above mean sea level
IP Rating
IP40
Vibration requirements
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements
3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC
Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients
0.1x (specified accuracy)/ °C
(<64> 82° F)
(<18> 28 °C)
Related Products
FLUKE 378 FC True-RMS AC/DC…
Fluke 377 FC True-RMS AC/DC…
FLUKE 902 FC TRMS HVAC Clamp…
UT207B 1000A True RMS Digital…
Fluke 374 FC True RMS Clamp…
FLUKE 375FC True RMS AC/DC…
FLUKE 373 True RMS AC Clamp…
FLUKE 369FC Leakage Current…
FLUKE 355 True RMS Clamp…
UT221 2000A Clamp Meter
UT219DS Professional Clamp…
Join Our Newsletter Now
Get E-mail updates about our latest shop and special offers.
Address: GooXoom.com
Salah Al Din Street
Deira, Dubai
United Arab Emirates